Sort By:
Show:

Siemens SITRANS

Part Number Description Group Stock Price Order
7MF1565-3BA00-1AA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1 bar, Overload- pressure 2,5 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BA00-1BA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1 bar, Overload- pressure 2,5 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male thread and G1/8" fenale thread Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BA00-1EA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1 bar, Overload- pressure 2,5 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: 1/4"-18 NPT male (standard for pressure ranges psi) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BA00-3GA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1 bar, Overload- pressure 2,5 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: Connection via mounted cable, 2m (not with explosion protection) Process connection: 1/2"-14 NPT male Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BA00-5EA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1 bar, Overload- pressure 2,5 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland 1/2" - 14 NPT (with connector) Process connection: 1/4"-18 NPT male (standard for pressure ranges psi) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BA00-5EB1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1 bar, Overload- pressure 2,5 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland 1/2" - 14 NPT (with connector) Process connection: 1/4"-18 NPT male (standard for pressure ranges psi) Sealing material between sensor and housing: Neoprene (CR) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BA00-5GA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1 bar, Overload- pressure 2,5 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland 1/2" - 14 NPT (with connector) Process connection: 1/2"-14 NPT male Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BA01-1AA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1 bar, Overload- pressure 2,5 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V with Explosion protection: EEx ia IIC T4 Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BA01-1BA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1 bar, Overload- pressure 2,5 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V with Explosion protection: EEx ia IIC T4 Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male thread and G1/8" fenale thread Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BB00-1AA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1,6 bar, Overload- pressure 4 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BB00-2ED1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1,6 bar, Overload- pressure 4 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: round plug M12 to DIN 60139-9 Process connection: 1/4"-18 NPT male (standard for pressure ranges psi) Sealing material between sensor and housing: EPDM Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BB01-1AA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 1,6 bar, Overload- pressure 4 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V with Explosion protection: EEx ia IIC T4 Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BD00-1AA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 2,5 bar, Overload- pressure 6,25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BD01-1AA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 2,5 bar, Overload- pressure 6,25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V with Explosion protection: EEx ia IIC T4 Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
7MF1565-3BE00-1AA1, SIEMENS SITRANS
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 4 bar, Overload- pressure 10 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P200 (7MF1565) 0 On Request
Go to page
Showing 1 - 15 of 567 (38 Pages)